Spirent TestCenter: How can I configure SyncE?

Environment/Versions
  • Spirent TestCenter.
  • SyncE (Synchronous Ethernet).
Answer
  • Open Spirent TestCenter Application, reserve at least one port, and create an emulated device.
  • Enable the SyncE option under Technologies... > Carrier Ethernet.
  • Under All Devices enable the Active checkbox for the Spirent emulated device that will run SyncE and select QL-PRC as the Quality Level.
  • If you need STC to be the slave, set the Quality Level to QL-PNU.
Important:
  • Confirm the SyncE Option value matches in both, the DUT and STC.  In STC you can find it under:
    • The SyncE tab under the port.
    • The SyncE tab under All Ports.


The device with the lower Quality Level (QL) will be the master.  Please refer to the table from below:
 
SSM QL (Binary) Standard Mappings Given in ITU-T G.781 Specification PTP Clock Class
  Option I Option II  
0001 - QL-PRS 80
0000 - QL-STU 82
0010 QL-PRC - 84
0111 - QL-ST2 86
0011 . . 88
0100 QL-SSU-A QL-TNC 90
0101 - - 92
0110 - - 94
1000 QL-SSU-B - 96
1001 - - 98
1101 - QL-ST3E 100
1010 - QL-STE/QLEEC2 102
1011 QL-SEC/QL-EEC1 - 104
1100 - QL-SMC 106
1110 - QL-PROV 108
1111 QL-DNU QL-DUS 110



 

Product : Spirent TestCenter,SyncE